ACSON Service Guide Book Table of Contents 1 Table of Contents 1.0 MODEL NAME 1.1 Product Name Description ...
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Controller Configuration 26 5.0 CONTROLLER SETTING 5.1 Auto Random Restart 5.2 Hot Keep Selection • Shorted a
ASCON Service Guide Book Controller Configuration 27 L2 Models Two selections are available: a. Fan ON: - If the indoor coil temperat
ASCON Service Guide Book Controller Configuration 28 5.3 Sequential Board (SQ2.0) Dip switch setting of sequential controller are as the f
ACSON Service Guide Book Model Name 2 1.0 MODEL NAME 1.1 Product Name Description No. Description Generic Model Name ACSON B
ASCON Service Guide Book Controller Configuration 29 6. Defrost Option Select whether compressor will turn off or remain on when 4WV chang
ASCON Service Guide Book Controller Configuration 30 5.4 Chilled Water Fan Coil Unit (W1V3) The standard W1V3 board comes with a VALVE jum
ASCON Service Guide Book Controller Configuration 31 5.5 Chilled Water Fan Coil Unit (W2.0) The system operating modes can be configured
ASCON Service Guide Book Controller Configuration 32 5.6 Hardware Setting – SLM9 There are 2 jumpers on SLM9 option to control the board f
ASCON Service Guide Book Controller Configuration 33 6.0 CONVERSION CONFIGURATION 6.1 Auxiliary Heater Conversion U1.5 Heatpump with Auxi
ASCON Service Guide Book Controller Configuration 34 SB125 Heatpump with Auxiliary Heater To convert SB125 heatpump PCB to auxiliary heate
ASCON Service Guide Book Controller Configuration 35 W2 Heatpump with Auxiliary heater To convert SB125 heatpump PCB to auxiliary heater a
ASCON Service Guide Book Controller Configuration 36 6.2 Multi Split Conversion Cooling Only Model (L2.0 / L208A) AWM-G, ACK-A/B/C/E, ACM
ASCON Service Guide Book Controller Configuration 37 6.3 U1.5 Æ L208A Conversion All single split indoor units with U1.5 PCB cannot be dir
ASCON Service Guide Book Controller Configuration 38 6.4 WMF U1.4 to L2EF Conversion 1. The U1.4 PCB can be replaced directly by the new
ACSON Service Guide Book Conversion Table 3 2.0 CONVERSION TABLE 2.1 Conversion Table Capacity Btu/hr MBH kCal/Hr kW 1 0.001 0
ASCON Service Guide Book Controller Configuration 39 6.5 SQ Board for Wiring up to 1000m Conversion Comparison of Sequential Main Board SQ
ASCON Service Guide Book Controller Configuration 40 Sequential LCD conversion for wiring up to 1000m Work Indication (WI): Step 1: Disma
ASCON Service Guide Book Controller Configuration 41 6.6 Room Sensor on Netware 3 There is a temperature sensor located at TH1 on the Net
ASCON Service Guide Book Diagnosis 42 7.0 SERVICE DIAGNOSIS 7.1 LED Lights Diagnosis Table Wall Mounted F Series Cooling Only Model
ASCON Service Guide Book Diagnosis 43 Wall Mounted F Series Heat Pump Model Board Handset AWM 10/15/20/25FR, 301R U1.5 G8 / SLM3 /
ASCON Service Guide Book Diagnosis 44 Wall Mounted G Series Model Board Handset AWM 10/15/20/25G/GR L2.2 G18 / SLM3 / Netware 3 /
ASCON Service Guide Book Diagnosis 45 Wall Mounted J Series Model Board Handset AWM 09/15J/JR L2GSN G18 SLEEP (Red) POWER (
ASCON Service Guide Book Diagnosis 46 Ceiling Cassette A / B / C Series Model Model Board Handset ACK 20/25/30/40/50A/AR U1.5 G8 / S
ASCON Service Guide Book Diagnosis 47 Ceiling Cassette A / B / C/ E Series Model Model Board Handset ACK 20/25/30/40/50A/AR L208A G18
ASCON Service Guide Book Diagnosis 48 Ceiling Exposed D Series Model Model Board Handset RCM 20/25/30/40/50D/DR U1.5 G8 / SLM3 / Ne
ASCON Service Guide Book
ASCON Service Guide Book Diagnosis 49 Ceiling Exposed D / E Series Model Model Board Handset RCM 20/25/30/40/50D/DR L208A G18 / SL
ASCON Service Guide Book Diagnosis 50 Chilled Water Fan Coil Unit Model Board Handset AWM 05 – 25FW, 301W W1V3 G8 / SLM3 / Netware
ASCON Service Guide Book Diagnosis 51 Water Source Split Unit – Wall Mounted G Series Model Model Board Handset A5WMWS 10/15/20/25GR
ASCON Service Guide Book Diagnosis 52 Water Source Split Unit – Ceiling Cassette A / B / C Series Model Model Board Handset A5CKWS 2
ASCON Service Guide Book Diagnosis 53 Wall Mounted F Cooling Only Inverter-X Model Model Board Handset AWMX 10/15F VA2.0 G18 / SLM3
ASCON Service Guide Book Diagnosis 54 Wall Mounted F Heatpump Inverter-X Model Model Board Handset AWMX 10/15FR VA2.0 G18 / SLM3
ASCON Service Guide Book Diagnosis 55 Wall Mounted G Series Inverter-X Model Model Board Handset AWMX 10/15/20/25G/GR VA2.0 G18
ASCON Service Guide Book Diagnosis 56 Ceiling Cassette A/C Series Inverter-X Model Model Board Handset ACKX 20/25A/AR VA3.0 G18 /
ASCON Service Guide Book Diagnosis 57 Ceiling Convertible E Series Inverter-X Model Model Board Handset ACMX 15/20/25E/ER VA3.0 G1
ASCON Service Guide Book Diagnosis 58 Inverter - X Outdoor Unit Model Board ALCX 10/15/20/25C/CR VB2.0 AMSV 25/35A VB2.0 AMSX 20/25
ASCON Service Guide Book
ASCON Service Guide Book Diagnosis 59 Inverter-Y Model Indoor Series Model Board Handset A5WMY 10/15/20/25 JR W_2_03A GS02 / G18
ASCON Service Guide Book Diagnosis 60 Single Split Inverter – Y Outdoor Unit Model Board A5LCY 10/15 DR S_2_03A A5LCY 20/25 CR S_
ASCON Service Guide Book Diagnosis 61 Multi Split Inverter – Y Outdoor Unit Model Board A5MSY 20/25/30 BR - The outdoor unit LED
ASCON Service Guide Book Diagnosis 62 7.2 Error Codes Diagnosis By Handset SLM 3 / Netware 3 / SLM 9 – On/Off Models Error Code Fau
ASCON Service Guide Book Diagnosis 63 Netware 3C / SLM 9 – Inverter Y Models (Except 5WMY-J/JR) Error Code Faulty Indication Error Cod
ASCON Service Guide Book Diagnosis 64 Sequential Controller (SQ LCD) – SB & RT Multi Compressors Error Code Faulty Indication Erro
ASCON Service Guide Book Diagnosis 65 Rooftop Panel Alarm Shown On The Rooftop Panel • Whenever panel received a new alarm, an alarm m
ASCON Service Guide Book Diagnosis 66 Condenser fan motor faulty Replace fan motor. Main PCB faulty Replace main PCB. 9. Disconnection
ASCON Service Guide Book Diagnosis 67 Chiller Panel – Air Cooled Mini Chiller When malfunctioning occurred, the display LCD will blink
ASCON Service Guide Book Diagnosis 68 G18 – Inverter Y Models Diagnosis Step 1. Hold down TIMER CANCEL button for 5 seconds, a “
ASCON Service Guide Book Handset Ope
ASCON Service Guide Book Diagnosis 69 GS02 – Inverter Y Models Diagnosis Step 1. Hold down ON TIMER CANCEL button or OFF TIMER C
ASCON Service Guide Book Diagnosis 70 Error Codes for G18 and GS02 – Inverter Y Models Error Codes Error Descrip
ASCON Service Guide Book Diagnosis 71 APJ2 –A5WMY10/15KR Indoor LED Indication The operation lamp (green) flashes when any of t
ASCON Service Guide Book Diagnosis 72 7.3 MDS Diagnosis (A)Indoor Units Model Board Handset A(5)WMD 09/10/15/20/25 G MC201-C G18
ASCON Service Guide Book Diagnosis 73 Error Diagnosis by Wired Controller (MC301) ITEM CODE DESCRIPTION 18 F3 Sensor Broken (indoor
ASCON Service Guide Book Diagnosis 74 (B) Outdoor Units Model Board Handset AMDS 30/40/50/60/70 A/AR V4.0 – V4.5 G18/ MC301 AMDS 80
ASCON Service Guide Book Diagnosis 75 7.4 General Check When any air conditioner malfunction is noted, immediately switch off the powe
ASCON Service Guide Book Diagnosis 76 7.5 General Troubleshooting Guide By means of pressure readings: Pressure Probable Cause Too L
ASCON Service Guide Book Appendix 77 APPENDIX A. Resistance – Temperature Characteristics Model ALL ON/OFF UNIT, FAN COIL UNIT R
ASCON Service Guide Book Appendix 78 Model A5WMY10/15KR; A5LCY10/15ER; A5LCY30/40/50/60FR Resistance R25=20.0kΩ + 1.0% - 1.0%
ASCON Service Guide Book Handset Oper
ASCON Service Guide Book Appendix 79 Model A5LCY30/40/50/60FR Discharge Pipe Sensor Resistance R25=230.0kΩ + 1.0% - 1.0% T°C R
ASCON Service Guide Book Appendix 80 B. MDS Compatibility Indoor PCB vs Wired Handset MC301 MC301 Indoor PCB B1.5 B1.6 B.17 B1.8
ASCON Service Guide Book Appendix 81 C. MDS Outdoor Capacity Dip Switch Setting MDS-B PCB version 2.3 and below: Dip Switch S3.1 S3.2
ASCON Service Guide Book Appendix 82 D. Cable Length of Wired Handset No. Wired Handset Cable Type Cable Length (m) Standard Optiona