Acson ACM20ER Especificações

Consulte online ou descarregue Especificações para Aparelhos de ar condicionado "split system" Acson ACM20ER. Acson ACM20ER Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Ceiling Convertible
Split Systems
ACM - E- 2007
ACM 15 E/ER
ACM 20 E/ER
ACM 25 E/ER
ACM 28 E/ER
A5CM 15 E/ER
A5CM 20 E/ER
A5CM 25 E/ER
A5CM 28 E/ER
Models:
Downloaded from AC-Manual.com Manuals
Vista de página 0
1 2 3 4 5 6 ... 124 125

Resumo do Conteúdo

Página 1 - Split Systems

Ceiling ConvertibleSplit SystemsACM - E- 2007ACM 15 E/ERACM 20 E/ERACM 25 E/ERACM 28 E/ERA5CM 15 E/ERA5CM 20 E/ERA5CM 25 E/ERA5CM 28 E/ERModels:Downlo

Página 2 - TABLE OF CONTENTS

Refrigerant Circuit DiagramsMODEL : ACM / A5CM 15E - ALC / A5LC 15C ACM 20E - ALC 18CACM / A5CM 20E - ALC / A5LC 20C A5CM 25E - A5LC 25CMODEL : ACM 25

Página 3 - 1. NOMENCLATURE

INDOOR UNITMODEL: ACM / A5CM 20/25EOUTDOOR UNITMODEL: ALC 18CALC / A5LC 20/25C98Downloaded from AC-Manual.com Manuals

Página 4

99INDOOR UNITMODEL: ACM / A5CM 28EOUTDOOR UNITMODEL: ALC / A5LC 28CDownloaded from AC-Manual.com Manuals

Página 5 - 2. PRODUCT LINE UP

100INDOOR UNITMODEL: ACM 28EOUTDOOR UNITMODEL: ALC 30CDownloaded from AC-Manual.com Manuals

Página 6 - ALC-C SERIES PRODUCT LINE UP

101INDOOR UNITMODEL: A5CM 28EOUTDOOR UNITMODEL: A5LC 35CDownloaded from AC-Manual.com Manuals

Página 7 - A5LC-C SERIES PRODUCT LINE UP

102HEATPUMPINDOOR UNITMODEL: ACM / A5CM 15EROUTDOORMODEL: ALC / A5LC 15CRDownloaded from AC-Manual.com Manuals

Página 8 - 3. FEATURES

103INDOOR UNITMODEL: ACM / A5CM 20/25EROUTDOORMODEL: ALC 18CRALC / A5LC 20/25CRDownloaded from AC-Manual.com Manuals

Página 9 - 4. APPLICATION INFORMATION

104INDOOR UNITMODEL: ACM / A5CM 28EROUTDOOR UNITMODEL: ALC / A5LC 28CRDownloaded from AC-Manual.com Manuals

Página 10 - A5CM 28E - A5LC 28C

105INDOOR UNITMODEL: ACM 28EROUTDOOR UNITMODEL: ALC 30CRDownloaded from AC-Manual.com Manuals

Página 11 - MODEL : ACM 28E - ALC 30C

106INDOOR UNITMODEL: A5CM 28EROUTDOOR UNITMODEL: A5LC 35CRDownloaded from AC-Manual.com Manuals

Página 12 - MODEL : A5CM 28E - A5LC 35C

1073 PHASE FOR 2 & 2.5 HP R410A OUTDOOR UNITMODEL: A5LC 20/25C (COOLING ONLY)3 PHASE / 50Hz / 380 - 415VMODEL: A5LC 20/25CR (HEAT PUMP)3 PHASE / 5

Página 13 - A5CM 25ER - A5LC 25CR

9MODEL : ACM 28E - ALC 28CMODEL : ACM 28E - ALC 30CDownloaded from AC-Manual.com Manuals

Página 14 - MODEL : ACM 28ER - ALC 30CR

10. SERVICING AND MAINTENANCE108Warning : Disconnect from main supply before servicing the air conditionerThe unit is designed to give long life opera

Página 15 - MODEL : A5CM 28ER - A5LC 35CR

109PRE START UP MAINTENANCE(AFTER EXTENDED SHUTDOWN)– Inspect thoroughly and clean indoor and outdoor units.– Clean or replace air filters.– Clean con

Página 16 - Controllers

11. TROUBLESHOOTINGWhen a malfunction of the air conditioner unit is detected, immediately switch off the main power supplybefore proceeding with the

Página 17 - SLM AC-5300 (OPTIONAL)

Diagnostic GuidelinesBy means of pressure reading:111 Pressure Data Circuit Too low A little low Normal A little high Too high Probable cause High

Página 18 - COOL DRY FAN HEAT

By means of diagnostic flow chart:Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failur

Página 19

113ii ) Diagnosis of Refrigerant Circuit / ApplicationThere might be some causes where the unit starts running but does not perform satisfactorily, i.

Página 20 - Figure A

114Satisfactory operation with temperature difference of air intake & discharge of indoor unit14°C to 20°C. *( * value is for reference only )Down

Página 21 - Floor standing type

12. EXPLODED VIEW & PARTS LIST115MODEL: ACM / A5CM 15/20/25/28 E/ER1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR N

Página 22

116MODEL: ALC / A5LC 15C1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Description Part

Página 23 - Floor standing installation

117MODEL: ALC 18 / 20C, A5LC 20C1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Descript

Página 24

10MODEL : A5CM 28E - A5LC 35CMODEL : ACM / A5CM 15ER - ALC / A5LC 15CRDownloaded from AC-Manual.com Manuals

Página 25

MODEL: ALC / A5LC 25 / 28C1181) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Description

Página 26 - To Adjust the Vane Direction

119MODEL: ALC / A5LC 15CR1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Description Par

Página 27 - Installation Clearance

120MODEL: ALC 18CR, ALC / A5LC 20CR1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Descr

Página 28 - (3) Refrigerant Piping

121MODEL: ALC / A5LC 25 / 28CR1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Descriptio

Página 29 - (6) Additional Charge

122MODEL: ALC 30C/CR, A5LC 35 C/CR1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICENo Description Part No No Descri

Página 30 - (7) Overall Checking

DOP:While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving forim

Página 31

11MODEL : ACM / A5CM 20ER - ALC / A5LC 20CRA5CM 25ER - A5LC 25CRMODEL : ACM 25ER - ALC 25CR ACM 28ER - ALC 28CRDownloaded from AC-Manual.com Manuals

Página 32 - Invert cylinder

MODEL : A5CM 28ER - A5LC 28CR12MODEL : ACM 28ER - ALC 30CRDownloaded from AC-Manual.com Manuals

Página 33

MODEL : A5CM 28ER - A5LC 35CR13Downloaded from AC-Manual.com Manuals

Página 34

G12 Remote ControllerTemperature Setting• To set the desired roomtemperature, press the button toincrease or decrease the settemperature.• The tempera

Página 35

151. “ON/OFF” switch• Press to start the air conditioner unit.• Press again to stop the unit.2. Temperature setting• Set the desired room temperature.

Página 36

COOL DRY FAN HEAT16Normal Operation / Fault Indication|Cool modeHeat modeAuto mode in heating operationAuto mode in cooling operationDry modeOutdoor c

Página 37

17Wired Remote Control – SLMCooling / Heatpump ModelError Code at 7 Segment Display Operation / Faulty IndicationBlink E1 Room sensor open or shortBli

Página 38

TABLE OF CONTENTS1. NOMENECLATURE ... 12. PRODUCT LINE

Página 39

InstallationSharp edges and coil surfaces are potential injury hazard. Avoid from contact with them.Caution(1) Installation of Indoor UnitPreliminary

Página 40

19Please ensure that the following steps are taken:• Check the gradient for drainage flow as recommended in Figure B.• Provide clearance for easy serv

Página 41

20Under Ceiling InstallationInstall the Suspension Bolts1. Install the suspension bolts so that it can support the indoor unit.2. Adjust the distance

Página 42

211. Refer to the dimension as illustrated when installing the mounting bracket.2. Determine the pipe hose position using the rear piping hole. Drill

Página 43

22Piping and Drain Hose InstallationUnder Ceiling Type1. The piping direction can be 2 ways as illustrated.2. The drain hose is only 1 way.Floor stand

Página 44

23How to Remove the Air Inlet Grille1. Remove the air inlet grille by both hands as the direction shown.2. Loosen the screws for fixing the panel arm

Página 45

24How to install the air filterTo Adjust the Vane DirectionAdjust the vane linkage as the direction shown to get the required vane direction.Dimension

Página 46

(2) Installation Of Outdoor UnitAs condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum

Página 47 - COMPONENTS DATA (R22)

26(3) Refrigerant PipingMaximum Piping Length And Maximum Number Of BendsWhen the pipe length becomes too long, both the capacity and reliability drop

Página 48

27(4) WiringElectrical Connections• Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRI-CAL CODES

Página 49

1. NOMENCLATURE1A CM 20ERBrandA : ACSONCapacity20 : 20,000 Btu/hSeriesE : E seriesModel TypeR : heatpumpOmitted if Cooling OnlyG IA C A-Refrigerant5 :

Página 50

28Diagram shows typical charging method:(7) Overall Checking• Ensure the following, in particular:1. The unit is mounted solidly and rigid in position

Página 51

29(9) Special Precautions When Dealing With Refrigerant R410a Uniti) What Is New Refrigerant R410A?R410A is a new HFC refrigerant which does not damag

Página 52

d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is toensure that only the original composition of R4

Página 53

5. ENGINEERING AND PHYSICAL DATA31GENERAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOT

Página 54

32GENERAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTE

Página 55 - COMPONENTS DATA (R410A)

33GENERAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTE

Página 56

34GENERAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Página 57

GENERAL DATA - HEATPUMP (R22)351) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Página 58

GENERAL DATA - HEATPUMP (R22)361) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Página 59

GENERAL DATA - HEATPUMP (R22)371) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Página 60

2A LC 20 C RBrandA : ACSONCapacity20 : 20,000 Btu/hSeriesC : C seriesModel TypeR : heatpumpOmitted if Cooling5 P OA C A-Refrigerant5 : R410AOmitted if

Página 61 - SAFETY DEVICES

GENERAL DATA - HEATPUMP (R22)381) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Página 62

39GENERAL DATA - COOLING ONLY (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TES

Página 63

40GENERAL DATA - COOLING ONLY (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TES

Página 64

41GENERAL DATA - COOLING ONLY (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TES

Página 65 - 6. PERFORMANCE DATA

GENERAL DATA - HEATPUMP (R410A)421) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED

Página 66

GENERAL DATA - HEATPUMP (R410A)431) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED

Página 67

GENERAL DATA - HEATPUMP (R410A)441) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED

Página 68

45COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inmm/

Página 69 - Performance Tables

46COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.ALC 18C ALC 20Cmm/inmm/inmm/incm3 / fl.o

Página 70

47COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inmm/

Página 71

INDOOR UNITACM-E SERIES PRODUCT LINE UPA5CM-E SERIES PRODUCT LINE UP32. PRODUCT LINE UPControl ModuleFinL2SLM3Netware IIIG12 HandsetCE MarkW/out Marki

Página 72

48COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.ALC 28C ALC 30Cmm/inmm/inmm/in 457 / 18

Página 73 - HEATING MODE

49COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inmm/

Página 74

50COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.ALC 18CR ALC 20CRmm/inmm/inmm/incm3 / fl

Página 75

51COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inmm/

Página 76

52COMPONENTS DATA (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.ALC 28CR ALC 30CRmm/inmm/inmm/in 457 / 1

Página 77

53COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inm

Página 78

54COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5CM 20E A5CM 25EA5LC 20C A5LC 25Cmm/i

Página 79

55COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5LC 28C A5LC 35Cmm/inmm/inmm/in 457 /

Página 80

56COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.mm/inmm/inmm/incm3 / fl.oz.mm/inmm/inm

Página 81

57COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5CM 20ER A5CM 25ERA5LC 20CR A5LC 25CR

Página 82

4OUTDOOR UNITALC-C SERIES PRODUCT LINE UPGrilleCap. TubeTXVGold FinHigh Ambient KitLow Ambient KitContactorHigh Pressure SwitchLow Pressure SwitchNant

Página 83

58COMPONENTS DATA (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5LC 28CR A5LC 35CRmm/inmm/inmm/in 457

Página 84

59SAFETY DEVICES1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.OPEN kPa / psiCLOSE kPa / psiOPEN kPa / psiCLO

Página 85

60SAFETY DEVICES1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.OPEN kPa / psiCLOSE kPa / psiOPEN kPa / psiCLO

Página 86

61SAFETY DEVICES1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.OPEN kPa / psiCLOSE kPa / psiOPEN kPa / psiCLO

Página 87

62SAFETY DEVICES1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.OPEN kPa / psiCLOSE kPa / psiOPEN kPa / psiCLO

Página 88

6. PERFORMANCE DATA63Interpolation and Extrapolation method can be used to get the total capacity, Q and sensible capacity, SC atthose temperatures wh

Página 89 - 7. DIMENSIONAL DATA

64Details:1st Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DBTotal ca

Página 90 - A5LC 20/25/28C/CR

652nd Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DBTotal capacity,

Página 91 - 8. ELECTRICAL DATA

663rd Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DBTotal capacity,

Página 92

67Performance TablesR22 MODELS(COOLING ONLY)MODEL : ACM 15E / ALC 15CMODEL : ACM 20E / ALC 18CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)

Página 93

5OUTDOOR UNITA5LC-C SERIES PRODUCT LINE UPGrilleCap. TubeTXVGold FinHigh Ambient KitLow Ambient KitContactorHigh Pressure SwitchLow Pressure SwitchNan

Página 94

68R22 MODELS(COOLING ONLY)MODEL : ACM 20E / ALC 20CMODEL : ACM 25E / ALC 25CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(k

Página 95

69R22 MODELS(COOLING ONLY)MODEL : ACM 28E / ALC 28CMODEL : ACM 28E / ALC 30CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(k

Página 96

70R22 MODELS(HEATPUMP)MODEL : ACM 15ER / ALC 15CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 97

71R22 MODELS(HEATPUMP)MODEL : ACM 20ER / ALC 18CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 98

72R22 MODELS(HEATPUMP)MODEL : ACM 20ER / ALC 20CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 99 - 9. WIRING DIAGRAMS

73R22 MODELS(HEATPUMP)MODEL : ACM 25ER / ALC 25CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 100 - MODEL: ALC 18C

R22 MODELS(HEATPUMP)MODEL : ACM 28ER / ALC 28CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC

Página 101 - MODEL: ALC / A5LC 28C

R22 MODELS(HEATPUMP)MODEL : ACM 28ER / ALC 30CRCOOLING MODEHEATING MODE75TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 102 - MODEL: ALC 30C

76R410A MODELS(COOLING ONLY)MODEL : A5CM 15E / A5LC 15CMODEL : A5CM 20E / A5LC 20C (1 PHASE)TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC

Página 103 - MODEL: A5LC 35C

77R410A MODELS(COOLING ONLY)MODEL : A5CM 20E / A5LC 20C (3 PHASE)MODEL : A5CM 25E / A5LC 25C (1 PHASE)TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 104 - MODEL: ALC / A5LC 15CR

Ceiling And Floor Installation OptionThe unit is uniquely designed with the option to install either below the ceiling or mounted at low wall position

Página 105 - ALC / A5LC 20/25CR

78R410A MODELS(COOLING ONLY)MODEL : A5CM 25E / A5LC 25C (3 PHASE)MODEL : A5CM 28E / A5LC 28CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC

Página 106 - MODEL: ALC / A5LC 28CR

79R410A MODELS(COOLING ONLY)MODEL : A5CM 28E / A5LC 35CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)158.685 5.95

Página 107 - MODEL: ALC 30CR

80R410A MODELS(HEATPUMP)MODEL : A5CM 15ER / A5LC 15CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Página 108 - MODEL: A5LC 35CR

81R410A MODELS(HEATPUMP)MODEL : A5CM 20ER / A5LC 20CR (1 PHASE)COOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 109 - 3 PHASE / 50Hz / 380 - 415V

82R410A MODELS(HEATPUMP)MODEL : A5CM 20ER / A5LC 20CR (3 PHASE)COOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 110 - 10. SERVICING AND MAINTENANCE

83R410A MODELS(HEATPUMP)MODEL : A5CM 25ER / A5LC 25CR (1 PHASE)COOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 111

84R410A MODELS(HEATPUMP)MODEL : A5CM 25ER / A5LC 25CR (3 PHASE)COOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Página 112 - 11. TROUBLESHOOTING

85R410A MODELS(HEATPUMP)MODEL : A5CM 28ER / A5LC 28CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Página 113 - Diagnostic Guidelines

86R410A MODELS(HEATPUMP)MODEL : A5CM 28ER / A5LC 35CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Página 114

87INDOOR UNITACM 15/20/25/28E/ERA5CM 15/20/25/28E/EROUTDOOR UNITALC / A5LC 15 C/CRNote : Dimension in mmNote : Dimension in mm7. DIMENSIONAL DATADownl

Página 115

4. APPLICATION INFORMATIONEnsure the operating temperature is in allowable range.Cooling onlyHeatpump7 Caution :The use of your air conditionerou

Página 116 - 14°C to 20°C. *

ALC 30C/CRA5LC 35C/CRNote : Dimension in mm88ALC 18C/CRALC 20/25/28C/CRA5LC 20/25/28C/CRMODEL A B C D E F G H I J K L M N O P Q R S T855 628 328 508 1

Página 117

8. ELECTRICAL DATA89ELECTRICAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL

Página 118 - MODEL: ALC / A5LC 15C

90ELECTRICAL DATA - COOLING ONLY (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TE

Página 119 - MODEL: ALC 18 / 20C, A5LC 20C

91ELECTRICAL DATA - HEATPUMP (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED

Página 120 - MODEL: ALC / A5LC 25 / 28C

92ELECTRICAL DATA - HEATPUMP (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED

Página 121

93ELECTRICAL DATA - COOLING ONLY (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING

Página 122

94ELECTRICAL DATA - COOLING ONLY (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING

Página 123 - MODEL: ALC / A5LC 25 / 28CR

95ELECTRICAL DATA - HEATPUMP (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Página 124

96ELECTRICAL DATA - HEATPUMP (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Página 125

9. WIRING DIAGRAMS97COOLING ONLYINDOOR UNITMODEL: ACM / A5CM 15EOUTDOOR UNITMODEL: ALC / A5LC 15CDownloaded from AC-Manual.com Manuals