A5CMY-E series A5CMY-E series
series
Ceiling Convertible
The ACM series promote easy service. For model
A5CMY15-28ER, all major components can be easily
access by removing the bottom panel. For the larger
range of A5CMY40/50ER, fan motor, blower & control
box can be reachable with ease by only pulling down
the intake grill.
The ACM series is designed with the option install the
either below the ceiling or in floor standing condition.
For model A5CMY15-28ER, the unit can be mounted
at low wall position*. The larger range of
A5CMY40/50ER will at floor standing condition.
*Wall bracket supplied as optional item for A5CMY15-28ER.
*R5CMY62CR is only applicable for under ceiling installation.
NEW
14 15
A5CMY 15/20/25E/ER
A5CMY 28/40/50ER
R5CMY 62CR
Cooling Capacity (kW) : 3.6 - 14.0
Heating Capacity (kW) : 3.8 - 16.7
Single-Split Y-Inverter Ceiling Convertible E-Series
This intelligent feature helps to detect faults or
malfunctioning in the system and give user a warning
by blinking of the LED lights.
The motorized louver enables the air flow to be evenly
distributed. At the same time, negative ion will be
released to provide air quality.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) & ISO 13253 (DUCTED PRODUCT)
3) COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
A) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
B) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER ACCORDING TO JIS C 9612 STANDARD.
- NON DUCTED PRODUCT: POSITION OF MICROPHONE IS 1.0M IN FRONT AND 0.8M UNDERNEATH THE UNIT.
- DUCTED PRODUCT: POSITION OF MICROPHONE IS 1.4 M UNDERNEATH THE UNIT AND WITH 2M RETURN & DISCHARGE DUCT LENGTH.
INDOOR MODEL
A5CMY15ER A5CMY20ER A5CMY25ER
OUTDOOR MODEL
A5LCY15DR A5LCY20CR A5LCY25CR
Btu/h 12249 (5936~14671) 18322 (5527~20199)
20608 (5323~21291)
W 3590 (1740~4300) 5370 (1620~5920) 6040 (1560~6240)
Btu/h 13170 (3650~16991) 19037 (5220~20199) 21086 (5596~21700)
W 3860 (1070~4980) 5580 (1530~5920) 6180 (1640~6360)
EER W/W 3.87 3.17 3.01
COP W/W 3.97 3.45 3.30
Type
V/Ph/Hz
INDOOR MODEL
A5CMY15E A5CMY20E A5CMY25E
OUTDOOR MODEL
A5LCY15D
A5LCY20C A5LCY25C
Btu/h 12249 (5936~14671) 18322 (5527~20199) 20608 (5323~21291)
W 3590 (1740~4300) 5370 (1620~5920) 6040 (1560~6240)
EER W/W 3.87 3.17 3.01
CFM 508/386/350 520/460/406 580/530/490
dBA 48/43/41 50/43/41 53/51/49
HEIGHT mm 212 212 212
WIDTH mm 1090 1090 1090
DEPTH mm 630 630 630
kg 25 27 27
SOUND PRESSURE LEVEL dBA 49 51 51
HEIGHT mm 550 753 753
WIDTH mm 765 855 855
DEPTH mm 285 328 328
kg 33 49 49
PRE-CHARGED m 7.5 7.5 7.5
MAXIMUM
m
15 30 30
LIQUID
mm
6.35 6.35 6.35
GAS
mm
12.70 12.70 15.88
COOLING
°C DB -10 ~ 46 -10 ~ 46 -10 ~ 46
HEATING
°C WB
-15 ~ 18
-15 ~ 18
-15 ~ 18
220-240/1/50
R410A
PIPE LENGTH
PIPE CONNECTION SIZE
REFRIGERANT
POWER SUPPLY
COOLING ONLY MODEL
RATED COOLING CAPACITY
(MIN ~ MAX)
ENERGY EFFICIENCY
OPERATING RANGE
(MIN~MAX)
UNIT DIMENSION
UNIT DIMENSION
UNIT WEIGHT
UNIT WEIGHT
INDOOR UNIT
OUTDOOR UNIT
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW (H/M/L)
HEATPUMP MODEL
RATED CAPACITY
(MIN ~ MAX)
COOLING
HEATING
ENERGY EFFICIENCY
INDOOR MODEL
A5CMY28ER
A5CMY40ER
A5CMY50ER
R5CMY62CR
OUTDOOR MODEL
A5LCY28CR
A5LCY40FR
A5LCY50FR A5LCY60FR
Btu/h 23200 (5801~25591)
34100 (17061~38557)
<34100 (31392~48794)>
43000 (20814~48452)
<42600 (24567~46746)>
47800 (19108~47770)
<44300 (33780~45040)>
W 6800 (1700~7500)
10000 (5000~11300)
<10000(9200~14300)>
12600 (6100~14200)
<12500 (7200~13700)>
14010 (5600~14000)
<13000 (9900~13200)>
Btu/h 26300 (39240~28321)
38900 (21155~55618)
<38200 (16378~55277)>
52900 (18767~55959)
<47770 (16378~55277)>
54300 (28231~55959)
<52800 (14672~57665)>
W 7700 (11500~8300)
11400 (6200~16300)
<11200 (4800~16200)>
15500 (5500~16400)
<14000 (4800~16200)>
15910 (8300~16400)
<15500 (4300~16900)>
EER W/W 2.81 3.05 <3.23> 3.50 <3.01> 2.87 <2.66>
COP W/W 3.01 3.90 <3.61> 3.55 <3.61> 3.51 <3.61>
Type
V/Ph/Hz
CFM 1053/968/883 1100/983/877 1215/1082/959 1550/1320/1000
dBA 56/51/44 52/47/46 52/50/49 56/53/46
HEIGHT mm 218 260 260 285
WIDTH mm 1080 1538 1786 1930
DEPTH mm 630 634 634 608
kg 27 45 65 70
SOUND PRESSURE LEVEL dBA 50 50 51 51
HEIGHT mm 753 1374 1374 1374
WIDTH mm 940 900 900 900
DEPTH mm 392 320 320 320
kg 51 100 100 100
PRE-CHARGED m 7.5 30 30 30
MAXIMUM m 50 75 75 75
LIQUID
mm 9.52 9.52 9.52 9.52
GAS
mm 15.88 15.88 15.88 15.88
COOLING
°C DB -10 ~ 46 -10 ~ 46 -10 ~ 46 -10 ~ 46
HEATING
°C WB
-15 ~ 18 -15 ~ 18 -15 ~ 18 -15 ~ 18
220-240/1/50 <380-415/3/50>
PIPE LENGTH
PIPE CONNECTION SIZE
REFRIGERANT
POWER SUPPLY - 1Φ <3Φ>
R410A
OPERATING RANGE
(MIN~MAX)
UNIT DIMENSION
UNIT DIMENSION
UNIT WEIGHT
UNIT WEIGHT
INDOOR UNIT
OUTDOOR UNIT
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW (H/M/L)
HEATPUMP MODEL
RATED CAPACITY
(MIN ~ MAX) - 1Φ <3Φ>
COOLING
HEATING
ENERGY EFFICIENCY
- 1Φ <3Φ>
220-240/1/50